Measuring a mass-transfer coefficient is slow: you weigh an evaporating pan or titrate a dissolving solid. Measuring a pressure drop or a heat-transfer coefficient in the same equipment is quick. Because momentum, heat and mass are all carried by the same eddies near a wall, one measurement can predict the others. That is the idea behind the analogies.
This lesson builds the three common analogies, shows the correction they need when the Prandtl and Schmidt numbers differ, and tests them against each other and against a correlation (Figure 1).
Known transferfriction factor or heat coefficient
j-factorput it in j form
Analogy
undo the group
Mass coefficient
Figure 1. Roadmap: a measured friction factor or heat-transfer coefficient becomes a mass-transfer coefficient through equal j-factors.
Learning Objectives
After this lesson, you should be able to:
State the Reynolds and Chilton-Colburn analogies with their j-factors, and say when each applies.
Predict a mass-transfer coefficient from a measured heat-transfer coefficient or friction factor.
Compare analogy estimates with a direct correlation and judge how far to trust them.
Key Ideas
1. The Reynolds Analogy
In turbulent flow next to a wall, the same eddies carry momentum, heat and solute. If the molecular diffusivities of all three are equal (), the profiles have the same shape and the transfer rates scale together:
Here is the Fanning friction factor and the bulk velocity. Each side is a Stanton number: mass, heat, momentum (Figure 2). The analogy holds only near with no form drag (Perry’s Eq. 5-312 and Table 5-19 row R; Geankoplis Eq. 7.3-12).
MassStanton number
same eddies
HeatStanton number
Pr and Sc near 1
Momentumwall friction
Figure 2. The Reynolds analogy: one turbulent flow sets all three Stanton numbers equal, provided and the drag is all skin friction.
Key idea: the Reynolds analogy says the Stanton numbers for mass and heat both equal . It needs and near 1.
2. The Chilton-Colburn j-Factors
Chilton and Colburn corrected the Reynolds analogy for real fluids by multiplying each Stanton number by its group to the two-thirds power. The result, the j-factor analogy, fits data for and (Welty, 5th edition, p. 539; Figure 3):
Momentum
no form drag
Heat
same flow, same geometry
Mass
Figure 3. The Chilton-Colburn bridge: equal j-factors link friction, heat transfer and mass transfer in the same flow.
Setting and cancelling gives the coefficient straight from a heat-transfer coefficient:
The correction factor is near 1 for gases, where and are both near 0.7, and far below 1 for liquids, where is in the hundreds (Figure 4).
Figure 4. The correction is close to 1 only when Pr and Sc are close; for a liquid it is about 0.05, so the simple Reynolds analogy would be off twentyfold.
The part holds for any geometry with the same flow. The part holds only when the drag is all skin friction, as in pipes and along plates. Past a sphere or through a bed, form drag raises without raising mass transfer (Figure 5).
Figure 5. The friction part of the analogy needs a drag that is all skin friction. Behind a sphere or in a bed, form drag inflates , so use from a mass-transfer correlation instead.
Key idea: is the safe half of the analogy. Use only for pipes and plates.
Worked Example 1: Evaporation Predicted from a Heat-Transfer Coefficient
Air at and flows over a wetted surface. Heat-transfer tests in the same flow gave . The partial pressure of water vapor is 3.0 kPa at the surface and 1.0 kPa in the bulk. Air properties at 300 K and 0.1 MPa: ,,,. For water vapor in air, at 273.15 K and 1 atm. Find and the evaporation flux. The steps are summarized in Figure 6.
Step 1: Prandtl number, diffusivity and Schmidt number. The diffusivity is corrected with :
Step 2: the analogy.
Step 3: flux. The water vapor is dilute, so the equimolar coefficient is used with :
That is of water.
Air properties
Heat to mass
factor 1.106
Coefficient
flux
Flux
Figure 6. Worked Example 1: from a heat-transfer coefficient to an evaporation flux in four moves.
Final Answer: and
Exam tip: if and are close, as here, the correction is small (1.11), but leaving it out still changes the answer by about 10 percent.
Your turn: flux from a heat-transfer coefficient
Same steps as Worked Example 1: set , correct with and , then multiply by the concentration difference.
Loading the practice problem…
3. The Prandtl Analogy
Prandtl improved the Reynolds analogy by splitting the wall region into a turbulent core and a thin laminar sublayer, where only molecular diffusion acts. With the sublayer edge at , the result for mass transfer (the Prandtl analogy, Perry Table 5-19 row T) is
For it reduces to the Reynolds analogy. It is better than the Reynolds form for of order 1, but for liquids the Chilton-Colburn form fits data better. Worked Example 2 compares all three on one pipe flow (Figure 7).
Worked Example 2: A Coefficient from a Friction Factor
Air at 300 K and 100 kPa (, as in Worked Example 1) flows at in a smooth pipe of diameter 0.025 m whose wetted wall evaporates water. A pressure-drop test gives a Fanning friction factor . Estimate with the Reynolds, Prandtl and Chilton-Colburn analogies, and compare with the Linton-Sherwood pipe correlation.
Step 1: Chilton-Colburn. A pipe has no form drag, so :
Step 2: Reynolds and Prandtl.
Step 3: check with a correlation., inside the Linton-Sherwood range, so and , 27 percent above the Chilton-Colburn value (Figure 7). Perry’s Table 5-19 row S notes that the Chilton-Colburn analogy runs about 20 percent low.
Figure 7. Worked Example 2: four routes to for the same pipe flow spread over almost a factor of two; the analogies are estimates, not exact results.
Final Answer: Chilton-Colburn (Reynolds 0.0350, Prandtl 0.0396, Linton-Sherwood 0.0621 m s-1)
Engineering note: a spread of 20 to 30 percent between an analogy and a correlation is normal; both are fits to scattered data. Report the method you used, and prefer a correlation measured for your geometry when one exists.
Your turn: a coefficient from a friction factor
Same steps as Worked Example 2: take and divide by .
Loading the practice problem…
Common Mistakes
Common mistake: using the friction factor for a sphere or a bed. Form drag raises without raising mass transfer, so overpredicts. Use or a mass-transfer correlation.
Common mistake: mixing friction-factor definitions. The analogies use the Fanning factor. A Darcy factor is four times larger; divide it by 4 first.
Common mistake: dropping the Schmidt correction for a liquid. For water, is about 0.05. The Reynolds analogy would overpredict about twentyfold.
Common mistake: inverting the correction. Heat to mass multiplies by ; mass to heat divides by it. A gas with gets a factor above 1, as in Worked Example 1. From a friction factor, : divide by , do not multiply.
Key Takeaway
Write every transfer rate as a j-factor and set them equal: for the same flow, only without form drag. Then or , good to about 20 to 30 percent.
Practice: randomized problems
Each problem below uses fresh numbers every time and mixes both kinds of problem in this lesson: work it out, check your answer, then open the worked solution to compare your steps.
Loading the practice problem…
Your results
This summary collects every practice problem you try on this page and suggests what to review next.
Loading your results…
Figures: original work by Dr. Ray’s Learning Center, licensed CC BY 4.0. Methods: Perry’s Chemical Engineers’ Handbook, 9th edition, Section 5 (Reynolds analogy, Eq. 5-312; Chilton-Colburn analogy, Eq. 5-313) and air properties from Table 2-110 and diffusivity from Table 2-141; C. J. Geankoplis, Transport Processes and Unit Operations, 3rd edition (equation numbers as printed in that edition), Section 7.3 (Eqs. 7.3-5 to 7.3-13); J. R. Welty, C. E. Wicks, R. E. Wilson and G. L. Rorrer, Fundamentals of Momentum, Heat, and Mass Transfer, 5th edition, Chapter 28 (Prandtl and Chilton-Colburn analogies; the j-factor range is on p. 539). Worked Example 2 uses an illustrative friction factor.